+31 (0)24 - 648 86 88 info@gotoPEO.com
nl
  • Nederlands
  • English
  • Français
Medical
Medical
icon
PEO
Photonics
Detection
Medical
Radiation
Service
Producten
Partners
Nieuws en events
Webinars
Referenties
Service
Contact
Medical
Service
Radiotherapie
  • Patiënt behandeling en monitoring
  • Intra-operatieve radiotherapie (IORT)
  • Dosimetrie
  • QA meetsystemen
  • QA fantomen
  • Positionering lasers
  • Plan verificatie
  • Protonen
  • Gafchromic film QA
  • Bloedbestraling indicatoren
  • Diversen & accessoires
Medische beeldvorming / Radiologie
  • QA fantomen
  • Training fantomen
  • Analyse software
  • Gafchromic film QA
  • Bloedbestraling indicatoren
Ga naar alle Medical producten
Medical
Micropos medical logo
SIT_Sordina-IORT-Technologies-Transparant_PEO-Medical
Ga naar alle Medical partners
20_PEO_radiation_technology_radiology_Maarten_Peters_Multi_Energy_CT_Phantom_Gammex_EN-NL
Medical bericht/Nieuws

Multi Energy CT fantoom: kwantificeren en constantheid checks van de CT

Multi Energy CT fantoomHet Multi Energy CT fantoom van Gammex is ontwikkeld voor het kwantificeren van jodium, patiënt equivalente weefsels en voor het controleren van de constantheid van CT-scanners.

Een van de vragen bij kwaliteitscontroles kan zijn of de weergegeven jodium concentratie de juiste is. Vooral tussen verschillende modellen of zelfs binnen identieke scanners bestaat er de kans dat er verschillen zijn in de constantheid. Met dit fantoom is het mogelijk materialen zoals jodium, metalen en weefsel equivalente materialen te classificeren.

Multi Energy CT fantoomDe weefsel equivalente staven (inserts) zijn voorzien van een identificatiemarker. De nieuwe rapidCHECK software zal deze automatisch herkennen als specifiek weefsel en zodoende ook zo analyseren.

De binnenste ring van het Multi Energy CT fantoom is eruit te schuiven. Het ACR464 fantoom of enkele Advanced iqModules™ van Gammex zijn eenvoudig in het fantoom te plaatsen, hetgeen een compleet proces van kwaliteitscontrole mogelijk maakt.

Met een extra set weefsel equivalente staven dient hetzelfde fantoom als een AED (Advanced Electron Density) fantoom en zodoende de CT gekalibreerd kan worden voor bestralingsplannen.

Voordelen Multi Energy CT fantoom:

  • uitgebreide tests van Multi Energy CT prestaties;
  • fantoom is één geheel (single-pour) (geen overbodige losse componenten);
  • staven eenvoudig in fantoom te schuiven;
  • kwantificeren van verschillende materialen/weefsels bij verschillende buisspanningen;
  • automatische herkenning en analyse in RapidCHECK 2.0 dankzij rod-marker technologie;
  • combinatie met ACR464 fantoom, iqModules, AED fantoom eenvoudig mogelijk.
  • test in configuraties met zowel kop (20 cm) als lichaam (40 cm x 30 cm) 2 mg / ml jodiumstaaf kwantificatienauwkeurigheid door mA’s voor 10 snelle kVp schakelende Multi Energy CT scanners.

Karakteristieken Multi Energy CT fantoom:

In-plane Dimensions: 40.0 cm (15.7 in) x 30.0 cm (11.8 in)
Depth: 16.5 cm (6.3 in), up to 26.5 cm (10.2 in) with extension plates
Material: Diameter of Removable Head Section:  20.0 cm (7.87 in) HE CT Solid Water®
Interchangeable Inserts: 18 solid inserts plus 1 true water container, each

tagged with a CT visible rod identification code

4 Iodine Inserts with

Variable Concentrations:

4 inserts with concentrations of 2.0,

5.0, 10.0, and 15.0 mg/mL

3 Iodine Inserts with

Variable Diameters:

5.0 mg/mL concentration at

diameters of 2.0, 5.0, and 10.0 mm

3 Calcium Inserts: Calcium concentrations of 50, 100, and 300 mg/mL

 

3 Blood Inserts: Blood-mimicking material at relative electron

densities of 1.03, 1.07, and 1.10

2 Blood with Iodine Inserts: Blood-mimicking material plus iodine at 2.0 and 4.0 mg/mL
3 Tissue-Mimicking Inserts: High-Equivalency Brain, High Equivalency Adipose, High Equivalency CT Solid Water
Weight: 15.5 kg (34.1 lbs)
Case: Wheeled case is included
Stand: Stand is included

Toepassingsgebieden:

  • radiotherapie
  • radiologie

Multi Energy CT fantoom productpagina

Datasheet (Multi Energy CT fantoom)

Sun Nuclear / Gammex product page

Wilt u meer informatie over dit fantoom of andere radiotherapie/radiologie fantomen of wilt u een demonstratie op locatie? Dat kan! Neem direct contact op met mp@gotopeo.comBlijf op de hoogte / Multi Energy CT fantoom

Meer informatie?
Neem contact op
Dit bericht komt uit ons archief en kan daardoor fouten bevatten in de opmaak.
Partner
Gammex

Al meer dan 40 jaar is Gammex een leider in de productie en distributie van Gammex Lasers patiënt alignment systemen en RMI Quality Control apparaten voor diagnostische beeldvorming en radiotherapie....


Ga naar de partner
Deel dit artikel

https://gotopeo.com/nl/medical/nieuws/multi-energy-ct-fantoom-gammex/

Kopieër de link
Email WhatsApp WhatsApp LinkedIn
Contact
+31 (0)24 - 648 86 88
info@gotoPEO.com
Havenweg 16, 6603 AS Wijchen
Watermolenstraat 2, 2910 Essen
Volg PEO op LinkedIn
Ga naar de contactpagina
Blijf op de hoogte in uw vakgebied
Ontvang het laatste nieuws over recente ontwikkelingen, promoties, events en wet- en regelgeving.

    Wij gebruiken uw e-mail adres enkel voor het versturen van onze nieuwsbrief.
    Leveringsvoorwaarden Privacy
    PEO B.V. © 2022 All Rights Reserved
    Producten
    Partners
    Nieuws en events
    Webinars
    Referenties
    Service
    Contact

    icon
    PEO
    Photonics
    Detection
    Medical
    Radiation
    Service

    Nederlands
    • Nederlands
    • English
    • Français

    NL +31 (0)24 - 648 86 88
    BE +32 (0)3 309 32 09
    info@gotoPEO.com

    LinkedIn
    Terug

    Producten

    Radiotherapie
    • QA fantomen
    • Training fantomen
    • Analyse software
    • Gafchromic film QA
    • Bloedbestraling indicatoren
    Medische beeldvorming / Radiologie
    • QA fantomen
    • Training fantomen
    • Analyse software
    • Gafchromic film QA
    • Bloedbestraling indicatoren

    Ga naar alle Medical producten
    Terug

    Partners

    Micropos medical logo
    SIT_Sordina-IORT-Technologies-Transparant_PEO-Medical

    Ga naar alle Medical partners
    PEO maakt gebruik van cookies.
    Als u onze website gebruikt, gaat u ermee akkoord dat we cookies plaatsen. Meer informatie vindt u in ons privacy statement.